服务培训
CH和CHI/CH CHI
CH泵性能曲线/CH curve range
CHI性能曲线/CHI curve range
铭 牌 说 明/Nameplate indication
CH/CHI产品型号说明/Instruction for pump type
CH的结构/Structure
CHI的结构/Structure
CH/CHI泵的应用/Application
一、CH的应用/Application for CH
轻工业领域的液体输送及循环/Liquid transportaion & circulation in light industry
增压/Boosting
家庭供水/Water supply in house
冷却系统/Cooling system
空调系统/Air-con system
CH/CHI泵的应用(续)/Application(Continued)
CH/CHI的技术参数/Technical date
CH/CHI的技术参数(续)/Technical date(continued)
*小入口压力/Min inlet pressure:不气蚀/No cavitation corrosion
*大入口压力/Max inlet pressure:取决于*大操作压力/Depend on the max operating pressure
电器数据/Electrical data:参见每个
电机的铭牌/See the nameplate of each motor
*大起停次数/Max star/stop times:100次/小时/100 times/hour
CH/CHI的安装/Installation
CH/CHI的安装(续)/Installation(continued)
CH/CHI安装中要注意的几个问题:/Please pay attention to the below factor in the installation procedure:
1、CH/CHI的
接线盒位置均可以在除底面以外的另三个面上自由设置(间隔90度)。/The terminal box can be positioned in any side of the motor in every 90 degree interval besides the below level.
2、安装管路时要避免气锁,特别是泵的吸入侧
CH/CHI的启动
1、完全关闭
水泵进出口阀门。
2、若吸入侧液位高于吸入口,则先取下泵体上的注水螺塞,再慢慢打开吸
入口阀门,使稳定液流从注水孔中流出。
3、若吸入侧液位低于水泵吸入口,则取下泵体上的注水螺塞,打开吸入侧阀
门,从注水孔向泵内灌注泵送液体,直至吸入管和水泵体完全充满泵送液
体。
4、起动水泵,慢慢打开出口侧阀门至全开。
5、从电机风扇端观察电机转向,若转向错误调整电机接线,恢复到正
确转向。正确转向已在风扇罩